product-details -77%

Fluke Digital HVAC Multimeter Fluke 116

$147.00 $635.00
0 Reviews

Categories :

Features:

  • Digital multimeter designed specifically for HVAC professionals
  • Includes built-in thermometer to measure temperature from -40C to 400C (-40F to 752F)
  • Provides microamps to test flame sensors
  • Features low input impedance to helps prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas

    The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment

    The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400C (752F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.

    Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

    Other useful features:

    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average to record signal fluctuations
    • Comes with a holster with probe holders for easy storage
    • Features a compact ergonomic design for one-handed operation
    • Fits into optional ToolPak magnetic hanger for hands-free operation
    • CAT III 600 V safety rate

    Includes:

    • TL75 test lead set
    • 80BK Integrated Temperature probe
    • Holster
    • Installed 9 V battery
    • User manual

    Specifications: Fluke 116 Digital HVAC Multimeter

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Safety IEC 61010-1: Pollution Degree 2
    IEC 61010-2-033: CAT III 600V
    Display Digital: 6,000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating temperature -10C to + 50C
    Storage temperature -40C to + 60C
    Battery type 9 volt Alkaline, IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts Range/resolution 600.0 mV / 0.1 mV
    Accuracy ([% of reading] + [counts]): 0.5% + 2
    DC volts Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ([% of reading] + [counts]): 0.5% + 2
    Auto volts Range/resolution 600.0 V / 0.1 V
    Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts1True RMS Range/resolution 600.0 mV / 0.1 mV
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts1True RMS Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity Range/resolution 600 / 1
    Accuracy Beeper on < 20 , off > 250 detects opens or shorts of
    500 s or longer.
    Ohms Range/resolution 600.0 / 0.1
    6.000 k / 0.001 k
    60.00 k / 0.01 k
    600.0 k / 0.1 k
    6.000 M / 0.001 M
    Accuracy 0.9% + 1
    Range/Resolution 40.00 M / 0.01 M
    Accuracy 5% + 2
    Diode Test Range/resolution 2.00 V / 0.001 V
    Accuracy 0.9% + 2
    Capacitance Range/resolution 1000 nF / 1 nF
    10.00 F / 0.01 F
    100.0 F / 0.1 F
    9999 F / 1 F
    100 F to 1000 F
    Accuracy 1.9% + 2
    Range/resolution > 1000 F
    Accuracy 5% + 20%
    Lo-Z Capacitance Range 1 nF to 500 F
    Accuracy 10% + 2 typical
    Temperature
    (Type-K thermocouple)
    Range/resolution -40C to 400C / 0.1C
    Accuracy 1% + 10
    Range/resolution -40F to 752F / 0.2F
    Accuracy 1% + 18
    AC A true-rms (45 Hz to 500 Hz) Range/resolution 600.0 A / 0.1 A
    Accuracy 1.5% + 3
    DC amps Range/resolution 600.0 A / 0.1 A
    Accuracy 1.0% + 2
    Hz (V or A input) Range/resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 Hz
    50.00 kHz / 0.01 Hz
    Accuracy 0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    4. Temperature Range/Resolution: -40F to 752F / 0.2F.
    Mechanical and General Specifications
    Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight 550 g
    Warranty 3 years
    Add a Review

    Your email address will not be published. Required fields are marked *